Door Closers and Floor Springs: QB/T 2698-2024 Scope and RFQ Fields

闭门器与地弹簧:现行标准适用范围与询单字段
2026-11-23
Door closersFloor springsQB/T 2698-2024
Door Closers and Floor Springs: QB/T 2698-2024 Scope and RFQ Fields

A door hardware schedule that says "closer, 200 pieces" leaves the supplier to guess the device, the mounting position, the handing and whether the opening is a fire door. Two Chinese industry standards were replaced on the same date in 2025, and the boundary between them is written into their scope clauses. Fix that boundary in the enquiry, then ask for the documents that go with it.

Which device falls under which current standard

QB/T 2698-2024, Door closer, is a current recommended light-industry standard on the national standards platform. It was published on 24 October 2024 and took effect on 1 May 2025, replacing QB/T 2698-2013 in full. The Ministry of Industry and Information Technology is the supervising department. The platform records CCS Y71, ICS 91.190, filing number 99000-2025 and filing announcement No. 3 of 2025. Its scope covers appearance, surface quality and performance requirements, the corresponding test methods, inspection rules, marking, packing, transport and storage, and a classification and designation system for use in technical specifications.

The same scope sets two limits that matter to a buyer. It applies to closing or opening devices mounted on the upper part of a swing door for single-direction opening. It does not apply to fire door closers. If the schedule covers a fire or smoke doorset, a report to QB/T 2698-2024 is not evidence for that doorset.

QB/T 2697-2024, Floor spring, carries the same publication and effective dates and replaced QB/T 2697-2013 in full; its filing number is 98999-2025. Its scope covers devices mounted above or below a swing door leaf that allow the leaf to open in both directions, and its requirements extend to installation. The platform page for QB/T 2698-2013 records it as withdrawn on 1 May 2025, and the Ministry announcement No. 28 of 2024 lists both 2024 editions together. A specification still naming the 2013 editions is naming withdrawn documents.

Device in the scheduleCurrent standardScope wording to quoteWhat sits outside it
Overhead closer, single-direction swing doorQB/T 2698-2024Mounted on the upper part of a swing door, for single-direction openingFire door closers
Floor spring, double-action leafQB/T 2697-2024Mounted above or below the leaf, opens in both directionsSingle-direction overhead closers
Closer on a fire or escape doorsetNot covered by QB/T 2698-2024Use the doorset evidence for the assemblyAny claim based only on a QB/T 2698-2024 report

The fire-door boundary in a submittal

The exclusion in QB/T 2698-2024 is explicit, and it is the most useful line in the standard for a specifier. A closing device on a fire door has to be shown as part of the tested and documented doorset: closer, hold-open device, hinges, lock or exit device, seals and the way the leaf is installed. Ask the supplier which doorset report and which field of applicability covers each item, and ask for the compatibility statement before the substitution is approved, not after the site inspection. Do not accept a closer datasheet as a substitute for that evidence. Our fire exit door with panic bar shows the kind of opening where this question arrives first.

That boundary is a scope question, not a product ranking. A closer can conform to QB/T 2698-2024 and still be the wrong item for a fire doorset, because the standard never set out to cover that use.

The EN product-standard map for export orders

For an export submittal, write the EN number that belongs to the device rather than a generic statement of compliance. BSI lists the building hardware product families and their standards in the scope of BS EN 17610:2022, which is recorded as Current, published 31 August 2022, under committee B/538/4. That scope assigns EN 1906 to lever handles, EN 1935 to single-axis hinges, EN 1154, EN 1155 and EN 1158 to controlled door closing devices, electrically powered hold-open devices and door coordinators, EN 12209 to mechanically operated locks and locking plates, EN 1303 to cylinders, EN 179 and EN 1125 to emergency and panic exit devices, and EN 14846 to electromechanically operated locks. The numbers tell you which product standard the declaration should refer to.

Confirm the edition year of each EN number on the standards body's own catalogue before it goes on the submittal. Several reseller catalogues give different amendment and corrigendum years for the same base number, and we do not carry those years into a specification without that check.

Doorsets and frames along a building corridor
Illustrative photo: doorsets along a building corridor. Editorial illustration only.

Fields to fix before the enquiry goes out

  1. Name the device and its mounting position: overhead, concealed in the frame or transom, or floor mounted.
  2. State single-direction or double-action opening, and the handing of each leaf.
  3. Give the measured leaf width, thickness and mass, plus the seal and latch resistance the closer must overcome.
  4. List the functions: hold-open, delayed action, backcheck, adjustable sweep and latching speed, and whether a hold-open device is electrically powered.
  5. Record the hole pattern, arm type and finish, and the corrosion environment of the opening.
  6. Say whether the opening is a fire or smoke door, and name the doorset evidence that must be matched.
  7. Name the target market, the standard number and its edition year, and the conformity marking required there.
  8. List the documents: type-test report, product marking, quality certificate, installation instruction and a sealed first article.

Which file answers which question

Question at goods-inFile to openRecord to keep
Is this the ordered device and mounting type?Quotation line and product markingReceiving sheet with the marking string
Is the standard edition current?Standards platform page and the type-test reportStandard number, year and report number
Does the device suit the doorset?Doorset report and field of applicabilityCompatibility statement and approval
Can the adjustment be repeated?Installation instruction and commissioning recordSigned commissioning sheet

Common document errors

The first is quoting the 2013 editions. The second is treating a power size number as a complete specification; a grade label without the leaf width, mass and the agreed standard tells the fabricator very little. The third is leaving the fire-door use off the enquiry and discovering it at handover. The fourth is substituting a cheaper closer on the quotation and assuming the doorset evidence still applies. The fifth appears in a lot of Chinese guides, where closing torque figures, cycle counts, salt spray hours, door mass tables, price bands and market size estimates are presented as selection rules. Those numbers come from vendor write-ups or from secondary readings of a standard text, and we have not verified them against an official platform. The same applies to older Chinese designations still repeated on encyclopedia pages. None of them belong in a submittal.

One more distinction is worth keeping. Hold-open devices, coordinators, hinges and locks are separate items with their own product standards, as the BSI scope list shows. Ordering them as one unspecified hardware set hides the fact that each one needs its own declaration and its own place in the doorset evidence. See door control hardware, hinges and door stops and holders for the item breakdown.

FAQ

Can a QB/T 2698-2024 test report be used for a fire door closer?

No. The scope of that standard states that it does not apply to fire door closers. Ask for the doorset report, the field of applicability and a written compatibility statement for the substitution, and keep the approval with the submittal.

Do we need to name the EN numbers on an order to China?

Only where the project's market and specification call for them. When they do, name the number that matches the device, for example EN 1154 for a controlled door closing device or EN 1935 for a single-axis hinge, and confirm the edition year on the standards body's catalogue. A generic conformity claim cannot be checked at goods-in.

What should the first enquiry contain?

Device type and mounting position, handing, measured leaf dimensions and mass, the functions required, the hole pattern and finish, whether the opening is a fire door, the target standard with its edition, and the document list. Send that sheet to our enquiry desk and we will return a quotation with each standard number and each required document marked against the item.