A thermal break order usually arrives as two different goods: the assembled thermal barrier profile that goes into the window frame, and the polyamide strip that the profile maker buys in. Two national standards govern them, and a quotation that mixes the two up will not survive an incoming inspection. Read the designation on each delivery before you sign the packing list.
GB/T 5237.6-2017, Wrought aluminium alloy extruded profiles for architecture, Part 6: Thermal barrier profiles, is current on the national standards platform. It was published on 14 October 2017 and took effect on 1 July 2018. The last review, dated 1 July 2025, concluded that it remains valid. It replaced GB/T 5237.6-2012 in full. The preparing body is TC243, the national technical committee for non-ferrous metals, with the China Nonferrous Metals Industry Association as the supervising department. The platform records CCS H61, ICS 77.150.10 and plan number 20140099-T-610.
GB/T 23615.1-2017 covers the strip itself. Its title is Thermal barrier materials for architecture aluminium alloy extruded profiles, Part 1: Polyamide profiles. It is current, published on 14 October 2017, effective 1 May 2018, and it replaced the 2009 edition whose title used the older wording "auxiliary materials, Part 1: polyamide thermal barrier strip". The official scope lists terms and definitions, requirements, test methods, inspection rules, marking, packing, transport, storage, the quality certificate and the content of the order or contract. That last item is the one buyers most often overlook: the standard tells you what belongs in the order.
Clause 4.4 of GB/T 5237.6-2017 joins the two. Polyamide profiles inside a strip-through profile have to comply with GB/T 23615.1. Polyurethane thermal barrier adhesive inside a poured profile has to comply with GB/T 23615.2. A certificate for the finished profile is not a certificate for the strip, and the other way round.
Clause 4.1.7 sets a fixed order for the marking: product name or composite method, the part number, the aluminium alloy designation and temper, the coating code and its performance class, written separately for the inner and outer faces when they differ, the shear failure type, the heat transfer class when that class is stated in the contract, the section code and cut length, the height of the insulation material, and the material code and performance class. The standard prints two worked markings, one for a strip-through profile using the material code PA66GF25 and one for a poured profile using PU. Treat those examples as a template for field order. Do not copy their values into your own order.
Clause 4.1.4 divides thermal barrier profiles into three shear failure types. Type A means a shear failure at the composite part does not affect transverse tensile performance, and is generally a strip-through profile. Type B means the shear failure leads to transverse tensile failure, and is generally a poured profile. Type O is a strip-through profile deliberately designed with little or no longitudinal shear resistance, for example to deal with thermal bowing of a door leaf. A, B and O describe behaviour under a defined failure mode. They are not a ranking, and asking for "the highest type" has no corresponding clause in a submittal.
Clause 4.1.6 adds a drawing requirement that belongs in the same paragraph of your enquiry: the cross-section of the thermal barrier profile is agreed between supplier and buyer, and the shape and dimensions of the slot are covered in Annex C. If the slot drawing is not attached to the order, the rolling and toothing operation has no agreed reference.
Clause 4.1.5 groups heat transfer coefficients into four classes, from I to IV, and links each class to a recommended service environment, a recommended polyamide profile height and a recommended poured-slot model. Clause 4.6 is the operative sentence for procurement: when the buyer requires a heat transfer coefficient, the class is agreed per Table 5 and written into the order or contract. The class is a negotiated field, not a number the supplier may assert on a datasheet. Nothing in these clauses turns a profile class into a whole-window thermal transmittance, and a specification that makes that jump should be sent back for correction.

The foreword of GB/T 23615.1-2017 works as a checklist of what changed. The standard was renamed, three normative references were deleted, namely GB/T 1036, GB/T 1633-2000 and GB/T 1634.1-2004, and three were added, namely GB/T 2035, GB/T 16825.1-2008 and GB/T 28289-2012. The classification, the marking and worked examples, the composition requirements, the ash requirements and the microstructure requirements were all revised. A supplier still working from the 2009 edition will quote a different marking and a different set of test methods.
The marking of the polyamide profile follows its own order: product name, part number, material code, dimensions written as product code by length by section height, and product category, which is omitted for non-Type-I profiles. The composition clause requires virgin polyamide 66 and does not permit recycled material. The ash clause defines what a calcination test should leave behind. Ask for the quality certificate, the marking on each bundle and the batch number that ties them together, then compare all three with the order.
| Field on the delivery | Where it is defined | What to compare it with |
|---|---|---|
| Composite method and part number | GB/T 5237.6-2017 clause 4.1.7 | The section drawing and the order line |
| Alloy designation, temper and coating codes | Clause 4.1.7, with GB/T 5237.1 to 5237.5 for the aluminium parts | The approved submittal |
| Shear failure type A, B or O | GB/T 5237.6-2017 clause 4.1.4 | The type named in the contract |
| Heat transfer class, when required | GB/T 5237.6-2017 clauses 4.1.5 and 4.6 | The class written into the order or contract |
| Strip material code and dimensions | GB/T 23615.1-2017 marking clause | The strip quality certificate and bundle marking |
The first is quoting the withdrawn editions. The second is treating A, B and O as a quality ranking. The third is letting a heat transfer class appear in a quotation without writing it into the contract, which leaves no agreed basis for a dispute. The fourth is writing a brand name in place of a material code; a brand tells you who supplied the strip, not what the standard requires of it. The fifth is accepting one certificate for two goods. The sixth appears in many Chinese buying guides, where the worked example's dimensions, hardness figures, glass fibre percentages, cycle counts and price bands are presented as selection rules. Those figures come from marketing write-ups, not from the procurement fields verified here, and we do not use them.
The same guides also confuse injecting sealant at a frame corner with the poured composite method in clause 4.1.4. They are different operations. Use the standard's own terms on the drawing and in the enquiry, and link the assembled window back to the system window, the thermal-break casement profiles and the sliding profiles only after the field check is done.
No. Clause 4.4 of GB/T 5237.6-2017 sends the polyamide profile to GB/T 23615.1 and the poured adhesive to GB/T 23615.2. These are separate product standards with their own marking, inspection rules and quality certificates. Ask for both documents and check that the batch numbers match.
There is no "highest" class to specify in isolation. Clause 4.6 requires the class to be agreed and stated in the order or contract when the buyer asks for a heat transfer coefficient. Start from the project's energy calculation, then write the agreed class into the contract and into the submittal, rather than into a marketing claim.
Name the composite method, the alloy and temper, the coating codes, the shear failure type, the cross-section drawing, the section code and cut length, the strip material code, and whether a heat transfer class is required. Ask the supplier to return the marking string filled in, plus the strip certificate and a sealed first article. Send that list with the polyamide thermal break strip item to our enquiry desk and we will return a marked-up specification against both standards.

QB/T 2698-2024 covers overhead closers and excludes fire door closers. QB/T 2697-2024 covers floor springs. Fix the scope first.