A hardware schedule that lists "handle, hinge, lock" without naming the opening type is not a schedule a fabricator can quote. A sliding sash and a tilt and turn sash do not share a load path, and the parts that hold one up are not the parts that hold the other. Write the opening form first, then list the components against it. GB/T 32223-2025 gives the structure for that list, and its annexes are where buyers most often read too much or too little.
GB/T 32223-2025, Building hardware for windows and doors: General requirements, is current on the national standards platform. It was published on 25 April 2025 and took effect on 1 November 2025, replacing GB/T 32223-2015 in full. The Ministry of Housing and Urban-Rural Development is the responsible department, and the national technical committee for building components is the preparing body. The platform records CCS Q73 and ICS 91.060.50. The 2015 edition is marked withdrawn, so a specification still quoting its clause numbers is quoting a document that no longer applies.
The official table of contents is short enough to use as a checklist. Chapter 4 is Classification and basic configuration. Chapter 7 is Requirements. Chapter 8 is Test methods. Annex A, informative, is Basic configuration of hardware for commonly used opening types. Annex B, normative, is Simulated windows and doors and test apparatus. The preface also records changed definitions for operating parts, load-bearing parts, transmission and locking parts, handles, rollers, transmission locks, multipoint locks and stays. Those definition changes matter when a supplier uses an older part name on a quotation.
Annex A is informative. It shows the minimum set of parts that a common opening form needs, and it is a useful way to count what is missing from a schedule. It is not a pass or fail criterion. Annex B is normative and covers the simulated window or door and the test apparatus used for the tests in Chapter 8. Chapter 7 carries the requirements. A buyer who treats the Annex A diagrams as an acceptance rule will reject a compliant kit for the wrong reason; a buyer who ignores Annex B will accept a type-test report that was not raised against the specified apparatus. Keep the three apart on the submittal: configuration from Annex A, requirements from Chapter 7, evidence from the test method and apparatus in Chapter 8 and Annex B.
The official drafting notes make the same point from the other side. Their materials section says the listed metals are recommended common materials and that the standard does not restrict new materials; where a non-listed material is used, the product still has to meet the performance requirements of the relevant hardware item. That is a performance instruction, not a brand list.
The drafting notes group hardware into four functional categories. Operating parts include the transmission handle, rotary handle, double-sided handle, single point lock, pull handle and window opener. Load-bearing parts include hinges, friction stays, rollers, glass door hinges, door clamps, floor springs and parallel-opening window stays. Transmission and locking parts cover transmission locks, multipoint locks and bolts. Auxiliary parts now include stays, lift assistance devices, anti-disengagement devices, fall prevention devices and temperature-controlled closing devices. The 2025 revision added several of those names to the definitions.
Table 3 of the drafting notes records the changes to basic configuration. Casement windows gained a lift assistance device. Sliding windows gained an anti-disengagement device. New opening forms were added to the configuration tables, including tilt and turn windows and parallel-opening windows, together with additional door types such as lift-slide and folding-slide doors. A schedule written from a 2015 template will miss those items. Ask the supplier to mark each of the four groups on the quotation, with the opening form written at the top.

The table below is a way to structure an enquiry, not a copy of the standard. Names of parts come from the categories above; the configuration column has to be checked against Annex A for the actual opening form on the drawing.
| Opening form | Parts to name on the enquiry | Reference to ask for |
|---|---|---|
| Inward or outward casement | Handle, transmission lock and lock points, hinge or friction stay, lift assistance device where the configuration calls for it | The Annex A configuration for that form, plus the Chapter 7 test evidence |
| Sliding | Rollers, track, latch or multipoint sliding lock, anti-disengagement device | The Annex A configuration, plus the roller and lock test reports |
| Tilt and turn | The complete linked set: handle, transmission mechanism, corner drive, hinges and lower pivot, stay and lock points | GB/T 24601-2024 as the product standard for the system |
| Top-hung or awning | Stay matched to the load direction, opener where specified, limit device, lock points | The Annex A configuration and the stay test report |
GB/T 24601-2024, Tilt and turn hardware system for building windows, was published on 23 August 2024 and took effect on 1 March 2025. It is current and replaced GB/T 24601-2009 in full. It shares the same technical committee as GB/T 32223-2025. A tilt and turn sash switches between inward opening and tilt ventilation through one linked mechanism; the handle position, corner drive, lower pivot and upper stay are designed as a set. Swapping a single part from a casement kit does not produce that system. On an enquiry, name the system standard and ask for one set of test evidence covering the whole mechanism. Our tilt and turn hardware systems page shows the form we supply.
It is informative. Use it to check that the schedule is complete, then use Chapter 7 and the test evidence to judge whether the parts pass. Annex B is normative and governs the simulated window and test apparatus.
No. It is a general requirements document. Individual hardware products still have their own standards, and the drafting notes describe the material chapter as recommendations rather than a closed list.
GB/T 32223-2015 is withdrawn on the national standards platform. Ask for the quotation to be reissued against the 2025 edition, with the part names from the revised definitions.
No. GB/T 24601-2024 is a separate product standard for the linked system. Ask for one type-test report that covers the whole mechanism rather than separate reports for loose parts.
The schedule with the opening form, the four groups of parts, the standard numbers with years, the type-test reports, material certificates and the sealed first article. Keep them under one purchase order.
Start by writing the opening form on the schedule. Send it with the drawing through the contact page, and we will return a quotation that names every part group against the sash it belongs to.

GB/T 5237.6-2017 and GB/T 23615.1-2017 govern two different goods. Read both markings before you sign the packing list.
Read more
QB/T 2698-2024 covers overhead closers and excludes fire door closers. QB/T 2697-2024 covers floor springs. Fix the scope first.
Read more
How to name the exact AAMA and GB/T edition on an aluminium finish enquiry, and what the 2026 FGIA revisions changed in the specification line.
Read moreSend us the categories, models or opening sizes you need. We will organise the configuration and quotation, in Chinese or English.