An enquiry that says "powder coated aluminium, RAL 7016" is not a finish specification. Two fabricators can quote it against different documents, and both can say they met the description. What separates them is the standard designation and its edition year. Write both on the enquiry before the colour, then keep the same wording on the quotation, the submittal and the first article record.
Standards get revised, and the designation changes with them. FGIA published three revised organic coating specifications on 19 May 2026: AAMA 2603-26, AAMA 2604-26 and AAMA 2605-26. FGIA states that the trio was last updated in 2022. A specification that says only "AAMA 2605" leaves the supplier without an instruction about which edition the price covers. The type-test report that arrives with the first article may then be raised against the older document, and the buyer has no written basis to reject it.
The 2026 revision changed the technical content as well. FGIA says the update provides additional guidance on pretreatment conversion coatings. Pretreatment sits under the coating and cannot be judged from a finished colour chip, so it belongs in the written finishing schedule. Ask the supplier to name the pretreatment and to state which edition of the coating specification that schedule follows.
All three documents share one long title: Voluntary Specification, Performance Requirements and Test Procedures for organic coatings on aluminium extrusions and panels, each with a coil coating appendix. The tier is what changes. AAMA 2603-26 covers pigmented organic coatings, AAMA 2604-26 covers high performance organic coatings, and AAMA 2605-26 covers superior performing organic coatings. FGIA describes the three as a good, better, best category of aluminium finishes, written to help the architect, owner and contractor specify factory-applied coatings that keep film integrity, exterior weatherability and general appearance over many years.
The FGIA store page for AAMA 2605-26 adds a detail that matters on panel work. This version includes an appendix describing differences in test procedures and performance requirements when AAMA 2605 coatings are applied on a coil coating line. Coil-coated stock and extrusions finished after fabrication are not specified the same way. Where a project uses both, the enquiry has to say which appendix governs each item.
AAMA 611-26 is a separate document for a different coating. Its FGIA store page describes test procedures and requirements for architectural quality aluminium oxide coatings applied to aluminium extrusions and panels for architectural products. That is an anodic coating rather than a pigmented organic one. The same page states the performance of an anodised finish with periodic maintenance in view. Listing AAMA 611 and AAMA 2605 as interchangeable options for one line item is the error we see most often on export enquiries. Pick the coating first, then name the document.
Chinese extrusion supply usually arrives with a GB/T 5237 part number. GB/T 5237.2-2017, Wrought aluminium alloy extruded profiles for architecture, Part 2: Anodized profiles, is current on the national standards platform. It was published on 14 October 2017 and took effect on 1 July 2018. Its review on 1 July 2025 concluded that it remains valid, and it replaced GB/T 5237.2-2008 in full. The series has six parts: mill finish, anodized, electrophoretic, powder coated, painted and thermal barrier profiles.
That is a product standard split by finish type. The FGIA documents are voluntary specifications for coating performance and test procedures. A part number from one system does not convert into a tier from the other. On a mixed order, list both references and say which items each one governs. Our earlier note on reading the GB/T 5237 series on a Chinese RFQ covers the domestic side in detail; this article stays with the edition line on an export enquiry.
For window and door profiles, curtain wall profiles and PVDF-coated aluminium veneer, the structure of the finish line should be the same even where the coating tier differs. Substrate, coating system, designation, edition, appendix, pretreatment and evidence belong on every line of the schedule.

Break the finish into fields a supplier can fill in without guessing. Copy the same table into the enquiry, the quotation and the first article record so that the three documents can be compared line by line.
| Field | What to write | What it controls |
|---|---|---|
| Substrate | Extrusion or panel, alloy and temper if the drawing fixes them | Which documents can apply at all |
| Coating system | Anodic coating, or pigmented organic coating | AAMA 611 against AAMA 2603 / 2604 / 2605, or the relevant GB/T 5237 part |
| Designation | Full document title and number | Removes brand shorthand and equivalence claims |
| Edition | Year suffix, such as 2605-26 or 5237.2-2017 | Which test procedures the price covers |
| Appendix | Whether the coil coating appendix applies | Coil-coated stock against finishing after fabrication |
| Pretreatment | Conversion coating named in the finishing schedule | The 2026 revision added guidance here |
| Evidence | Type-test report number, first article, sealed sample | What the fabricator hands over before shipment |
| Maintenance | Cleaning and inspection wording taken from the document | Anodised performance is stated with periodic maintenance |
The documents are sold through the FGIA store, and a fabricator who applies them needs the text. The buyer only needs to name designation and edition correctly on the enquiry and ask for the test evidence that follows from it.
Only if the specification says so. If the enquiry names AAMA 2605-26, a quotation based on the 2022 edition is a different offer. Put the edition in the quotation template so the difference is visible before the order is placed.
The appendix addresses coatings applied on a coil coating line to aluminium architectural products. State which items are coil-coated and which are finished after fabrication, then ask the supplier to confirm the applicable appendix for each.
Not as a substitute. It is a product standard for the profile, while the FGIA documents are coating performance specifications. Mixed orders normally carry both, each tied to the items it covers.
A sealed sample, the finishing schedule with pretreatment named, and the type-test report referenced by the designation on the enquiry. Keep all three against the same purchase order.
Start with the edition line. Send the finished schedule with your enquiry through the contact page, and we will return a quotation that names the document and the year on every coated item.

GB/T 5237.6-2017 and GB/T 23615.1-2017 govern two different goods. Read both markings before you sign the packing list.
Read more
QB/T 2698-2024 covers overhead closers and excludes fire door closers. QB/T 2697-2024 covers floor springs. Fix the scope first.
Read more
GB/T 32223-2025 puts basic configuration in Chapter 4 and lists opening types in an informative annex. Here is how to turn that into a hardware enquiry.
Read moreSend us the categories, models or opening sizes you need. We will organise the configuration and quotation, in Chinese or English.