Writing simply silicone sealant on an enquiry sheet is one of the easiest ways to create a problem in window and curtain wall sealing. The word can refer to a structural sealant, a weatherproofing sealant, a glazing sealant, a secondary seal for insulating glass, or an ordinary decorating caulk. Their governing standards, load-bearing role, ability to accommodate joint movement and compatible substrates are all different. Many online buying guides also treat a standard number as a performance grade and quote unsourced figures. This article rebuilds the subject from the current standard text: what GB/T 14683-2017 actually classifies, how to read the marking on the cartridge, how to select by joint type, and which fields an order must state.
Silicone sealant is a broad family named after its main ingredient. A weatherproof sealant is one application-specific member of that family, formulated for higher UV resistance and movement capability on exposed joints. Similar names, very different uses. Four functional groups are a useful starting point:
| Group | Typical location | Current standard | Load-bearing? |
|---|---|---|---|
| Structural sealant | Glass-to-frame bonding in hidden or semi-hidden curtain walls; secondary seal of insulating glass | GB 16776-2025 (mandatory) | Yes; joint dimensions set by design calculation |
| Weatherproof / construction joint sealant | Joints between curtain wall panels; outer frame-to-wall joint | GB/T 14683-2017 (recommended) | No; assessed for movement capability and weathering |
| Window and glazing sealant | Non-structural seal between frame and glass; interior trim joints | GB/T 14683-2017 (recommended) | No; focus on substrate compatibility and mould resistance |
| Secondary sealant for insulating glass | Structural edge bond of the unit | GB 16776-2025 (mandatory; this use is now consolidated into the new edition) | Yes; works as a system with butyl, spacer and desiccant |
The conclusion is blunt: structural and weatherproof sealants must not be substituted for one another. Industry codes explicitly prohibit downgrading structural sealant for weatherproof caulking, and a weatherproof sealant cannot take structural load. The first can create internal stress through mismatched cure; the second is a safety risk. For the boundary between these groups and the new structural standard, see the first article in this series, what changed in GB 16776-2025.
A common mistake is to answer how good is this sealant with it complies with GB/T 14683. That states only the standard the product is made to, nothing about the material, the intended location, or how much joint movement it can take. The letter T matters too: GB is mandatory, GB/T recommended.
GB/T 14683-2017, Silicone and modified silicone sealants for building, was published on 7 September 2017 and took effect on 1 August 2018, replacing the 2003 edition; it is the current recommended standard. Its scope covers silicone sealants for general decorating and for non-structural assembly in building curtain walls, and modified silicone sealants for construction joints and joints subject to drying shrinkage. Any load-bearing structural application falls outside this standard.
Chapter 4 of the standard classifies products in four layers. All four are needed to write a complete marking. Take them in order.
Silicone building sealant is marked SR, based mainly on polysiloxane. Modified silicone building sealant is marked MS, based mainly on silyl-terminated polyether. These are two different material systems, not two versions of one product.
Products are classified as single-component (I) or multi-component (II), which determines whether mixing is required before application. Multi-component products also introduce a pot-life requirement.
This layer is most often omitted, because SR and MS do not share the same use classes:
| Type | Use code | Meaning |
|---|---|---|
| SR silicone | F | Construction joints |
| SR silicone | Gn | Glazing for general decorating; not for insulating glass |
| SR silicone | Gw | Non-structural assembly in building curtain walls; not for insulating glass |
| MS modified silicone | F | Construction joints |
| MS modified silicone | R | Joints subject to drying shrinkage, common in joints between precast concrete facade panels |
Not for insulating glass is a limitation written into the standard, not a marketing phrase. The edge of an insulating glass unit is a structural seal and belongs to the scope of GB 16776-2025.
Products are graded by movement capability under GB/T 22083-2008, Classification and requirements for building sealants (current, reaffirmed on review in 2025, a modified adoption of ISO 11600). The standard defines four grades: 50, 35, 25 and 20, where the number expresses the percentage of joint movement the sealant can accommodate. A higher grade tolerates more joint opening and closing. A sub-grade divides tensile modulus into high modulus HM and low modulus LM.
One widespread error is worth correcting: some articles describe the movement grades as 25, 20 and 12.5, or present 12.5 as a grade under this standard. That conflicts with the four grades in Table 1 of the standard. Other guides claim a certain building height forces a particular grade; such thresholds have no basis in the standard and are not acceptance criteria. The correct approach is to determine the required grade from the design joint movement, then demonstrate compliance with a test report.
A product is marked in the order of name, standard number, type, grade and sub-grade. The standard gives these examples:
Silicone sealant (SR) GB/T 14683-I-Gn-25HM: single-component, glazing use, grade 25, high modulus.Modified silicone sealant (MS) GB/T 14683-II-R-20LM: multi-component, drying-shrinkage joints, grade 20, low modulus.Once the marking makes sense, an order should no longer say one cartridge of neutral weatherproof sealant. It should state type, components, use code, grade and sub-grade. Together, those five items locate a specific product.
It is a question of substrate compatibility, not quality. Acidic sealants cure quickly and bond well to some interior glass and ceramic substrates, but their by-product corrodes aluminium, coated glass and stone. Because windows and curtain walls involve metals and coated glass, neutral systems are the norm. Start with the substrate, then the application.
HM is high modulus and LM low modulus. This sub-grade is a separate dimension from the movement grade. A low-modulus sealant pulls less on the joint, but the choice depends on design joint movement, substrate and the designer requirement. Harder is stronger is not a valid rule here.
No. Codes prohibit substitution in either direction. Arrange replacement stock with the supplier, or have the designer assess an equivalent compliant product, record the change, and restore the specified weatherproof sealant as soon as possible.
Not necessarily. The grade has to match the design joint movement, joint width and detail, alongside modulus, elastic recovery and weathering performance. Chasing the highest grade without checking the detail and the report simply adds cost to an unnecessary specification.
Check three things: whether the standard number includes the year and is a current edition; whether the grade list matches Table 1 of the standard; and whether performance figures point to a verifiable type-test report rather than industry experience. If any one is missing, ask the supplier for more documentation.
Stating type, components, use, grade and sub-grade on the enquiry sheet is far more useful than memorising a dozen trade names. To check how weatherproofing products combine with window and stone sealants, or to confirm structural-side documentation, see the new structural standard explained. Send joint details and a substrate list via the contact page for an item-by-item reply against current standards.

GB/T 5237.6-2017 and GB/T 23615.1-2017 govern two different goods. Read both markings before you sign the packing list.
Read more
QB/T 2698-2024 covers overhead closers and excludes fire door closers. QB/T 2697-2024 covers floor springs. Fix the scope first.
Read more
How to name the exact AAMA and GB/T edition on an aluminium finish enquiry, and what the 2026 FGIA revisions changed in the specification line.
Read moreSend us the categories, models or opening sizes you need. We will organise the configuration and quotation, in Chinese or English.