"Send us window gaskets" is not a specification. On a doorset or a curtain-wall joint, a gasket may be expected to stop driving rain, hold back smoke in a fire, or simply stay elastic after years of compression. Those are three different failure modes, and no single strip is designed to solve all three. Worse, trade articles routinely use the words "swelling", "intumescent" and "firestop" as if they were interchangeable. This guide separates the functions, shows how to read a Chinese designation under GB/T 24498-2025, and ends with an RFQ checklist you can paste into an enquiry.
| Failure mode | What the gasket has to do | Where it is normally specified |
|---|---|---|
| Water ingress at a joint | Swell on contact with water to close a construction gap | Construction joints, below-grade and wet-area waterproofing details |
| Fire and smoke spread | Expand under heat to seal a gap, or provide smoke tightness as part of a rated assembly | Fire-rated doorsets, rated glazing and firestopping details, always within a tested assembly |
| Long-term compression and weather | Keep a resilient sealing line against air and rain over repeated opening cycles | Window and door perimeter seals, curtain-wall joints, everyday weather seals |
The first two rows are frequently confused because both products are sold as "expanding strips". A water-swelling strip responds to water; an intumescent strip responds to heat. They are not substitutes, and a smoke seal is again a different requirement tied to the doorset as a whole. The third row is the everyday sealing job, where material ageing and compression recovery matter more than any expansion behaviour.
GB/T 24498-2025, Sealing gaskets for building doors, windows and curtain walls, was issued on 24 January 2025 and took effect on 1 August 2025; it is the current national standard. The official standard record is maintained by the national standards information platform, and the implementing date is listed in the 2025 No. 2 announcement of national standards. Its classification gives buyers a vocabulary that does not depend on a supplier's product nickname.
The standard divides gaskets into single-material gaskets and composite weatherstrips. Table 1 lists four common single-material designations: EPDM (ethylene-propylene-diene rubber), MVQ (silicone rubber), TPV (thermoplastic vulcanisate) and TPS (styrenic thermoplastic elastomer). A note to that table says plasticised PVC (PPVC) material performance follows the thermoplastic-elastomer requirements; PPVC is a table note, not a separate category code in Table 1. A gasket with a flame-retardant function adds the suffix Z to the designation. Table 2 composite designations include FH-HM (sponge composite), FH-JX (wire-reinforced), FH-BF (wrapped sponge), FH-RY (soft-hard), FH-PZ (water-swelling composite) and FH-DMC (low-friction composite).
The marking is built from the product name, the standard number GB/T 24498, the material category code and a density code. That structure is what you should see on a compliant document. Ask for the full designation on the quotation, the packing label and the inspection record; a quotation that only says "EPDM strip" or "fire expansion strip" has not told you what is being supplied.
| Location | Primary risk | What to ask the supplier |
|---|---|---|
| Window and door perimeter, opening leaf | Air leakage, rain, loss of elasticity | Material category code, the density code, and the profile drawing matched to the groove |
| Curtain-wall and facade joints | Weather sealing plus movement accommodation | Whether the composite construction is intended for this joint, and the section geometry |
| Construction joints in wet areas | Water ingress through a static gap | Explicitly a water-swelling type (FH-PZ where the composite designation applies), not an intumescent product |
| Fire-rated doorset perimeter | Smoke and hot gas passage | The assembly's tested evidence, the flame-retardant or intumescent designation, and the field-of-application limits |
| Low-friction sliding interfaces | Wear and drag on a moving part | Whether a low-friction composite designation is specified for that contact surface |
Notice that the third and fourth rows demand different evidence. A waterproofing detail needs a product that behaves in water; a rated doorset needs evidence about the whole assembly, because replacing one component can invalidate the test evidence behind the rating. See our water-swelling gasket and intumescent seal pages for how we separate these two enquiries.
Trade copy often promises a single "composite" gasket that seals, swells and resists fire at once. Composite construction is a real category in GB/T 24498-2025, but it describes how a profile is built, not a licence to collapse three functions into one unverified claim. A soft-hard composite, for example, combines a resilient sealing lip with a firmer fixing base. That is a mechanical design choice. It says nothing by itself about fire performance or about swelling in water.
The practical rule is to write the function first and the construction second: name the risk, name the location, then choose the material or composite code that serves it. Where a project genuinely needs both an everyday weather seal and an intumescent function at the same perimeter, ask for the assembly evidence rather than accepting a single product name. Our EPDM gasket range covers the everyday weather-sealing side of that distinction.

For the incoming-goods inspection sequence itself (how to read the marking, what to record and when to reject), see our earlier GB/T 24498-2025 gasket inspection guide. The present article is about selecting the right function before that inspection happens. If you need help mapping a joint detail to a designation, contact us with the section drawing.
No. One responds to water in a waterproofing joint; the other responds to heat within a rated assembly. The GB/T 24498-2025 composite code FH-PZ identifies the water-swelling composite family.
Under GB/T 24498-2025, a gasket with a flame-retardant function adds Z to the designation. A suffix is a material/function marker, not a fire classification for the whole doorset.
The 2025 edition, issued 24 January 2025 and effective 1 August 2025. Confirm the version on the supplier's document rather than relying on an undated reference.
Write the functions as separate requirements and ask for supporting evidence for each. Composite construction describes how a profile is made; it does not by itself prove fire or waterproofing performance.
Specify the designation, the section drawing and the acceptance documents. Numeric performance values should come from the supplier's declared, verifiable data and the project design, not from an unsourced marketing article.

GB/T 5237.6-2017 and GB/T 23615.1-2017 govern two different goods. Read both markings before you sign the packing list.